COD Set-Up MD200
With four measuring ranges, the MD200 COD Set-Up provides the flexibility to analyse samples with different levels of organic contamination. Low, Middle-Low and Middle Range methods comply with ISO 15705:2002, supporting routine wastewater, environmental and process water analysis.
Suitable for laboratories, wastewater treatment facilities and industrial applications, the MD200 COD Set-Up provides a complete solution for efficient, repeatable COD analysis.
Simple, Reliable COD Testing
The MD200 COD Set-Up uses the established sealed-tube method to simplify routine COD analysis and minimise sample handling. Simply add the water sample to a Lovibond® ST-COD tube, digest at 150 °C for two hours, then measure the prepared sample using the MD200 photometer.
Ready-to-use, prefilled ST-COD tubes make sample preparation straightforward and help reduce handling and the potential for operator error. The MD200 then uses photometric measurement to determine the COD concentration, providing consistent results for routine water quality monitoring.
The combination of prefilled reagents, controlled digestion and photometric analysis creates a straightforward workflow for regular COD testing.
Flexible Measurement Across Different Water Samples
The MD200 COD Set-Up supports four measuring ranges, allowing the appropriate method to be selected according to the sample and expected COD concentration. Low, Middle-Low and Middle Range methods comply with ISO 15705:2002, providing a recognised approach to routine COD analysis.
For samples containing chloride, selected ST-COD methods incorporate chemistry designed to suppress chloride interference. This provides interference suppression up to 1,000 mg/L chloride for Low and Medium Range methods and up to 10,000 mg/L for the High Range method.
Mercury-free ST-COD tube tests are also available for applications where chloride interference is not present, providing an alternative option for suitable water samples.
Key Features
- Complete solution for routine COD analysis
- MD200 photometer for photometric COD measurement
- Four measuring ranges for different water samples
- Low, Middle-Low and Middle Range methods compliant with ISO 15705:2002
- Ready-to-use, prefilled ST-COD tube tests
- Straightforward sealed-tube digestion method
- Accurate, repeatable photometric measurement
- Chloride interference suppression up to 1,000 mg/L for LR and MR methods
- Chloride interference suppression up to 10,000 mg/L for the HR method
- Mercury-free tube tests available for suitable applications
- Suitable for routine laboratory water analysis
Applications
- Wastewater Treatment
- Raw Water Monitoring
- Industrial Water Analysis
- Environmental Water Monitoring
- Process Water Monitoring
| Order Code | Parameter | Test Parameter | Measuring Range |
|---|---|---|---|
| 2892602 | COD Set-Up MD200 | COD HR TT COD LMR TT COD LR TT COD MR TT | 200 - 15000 mg/L COD 15 - 300 mg/L COD 3 - 150 mg/L COD 20 - 1500 mg/L COD |
Reagents
| Order Code | Title | Measuring Range | Pack Size |
|---|---|---|---|
| 2420710 | COD LR/25 - Mercury Free | 3 - 150 mg/L O2 | 25 |
| 2420711 | COD MR/25 - Mercury Free | 20 - 1500 mg/L O2 | 25 |
| 2420712 | COD HR/25 - Mercury Free | 0.2 - 15 g/L O2 | 25 |